Associate Industries offers welding cables 100% HOFR with minimum one year guarantee. 'Associate' brand welding cables come with copper & aluminium conductor and insulated with HOFR synthetic Rubber confirming to IS : 9857 / 90. Cables are tested by ISI, Quality Marking Center and Regional Test House and were found confirming to IS requirements.
'Associate' recommends you to check the correct quantity by checking the size and quality by checking the resistance of the conductor in any cable. Formula for calculating the size has been given below and the resistance can be measured by milli-ohm-meter.
For more details please contact us.
Formula for calculating the size of the Cable:
Selection of Welding Cable
| Size (Sq.mm) |
Equivalent Cable as Specified in IS 434 |
Suitable for Welding Electrode upto |
| Copper |
Aluminium |
| 16 mm² |
25 mm² |
150 Amps. |
3.15 mm ( 10 SWG ) |
| 25 mm² |
35 mm² |
230 Amps. |
4.00 mm ( 8 SWG ) |
| 35 mm² |
50 mm² |
400 Amps. |
4.00 mm ( 8 SWG ) ¤ |
| 50 mm² |
70 mm² |
600 Amps. |
5.00 mm ( 6 SWG ) |
| 70 mm² |
95 mm² |
800 Amps. |
6.30 mm ( 4 SWG ) |
| 95 mm² |
120 mm² |
1000 Amps. |
Specially for automatic use |
- For any welding set, select size for highest size of electrode in use
- ¤ For longer length than 15 Meters
|
Go Top
Copper Welding Cable:
Construction:
| Cross sectional area of Cond. |
Diameter of wire |
Dia. of wire Rope |
Polyester Tape Thickness |
Nominal Sheath Thickness |
Max. Overall Diameter |
| 16 mm² |
0.2 mm |
6.0 mm |
0.025 mm |
2.0 mm |
10.5 mm |
| 25 mm² |
0.2 mm |
7.5 mm |
0.025 mm |
2.0 mm |
11.5 mm |
| 35 mm² |
0.2 mm |
9.0 mm |
0.025 mm |
2.0 mm |
13.5 mm |
| 50 mm² |
0.3 mm |
10.5 mm |
0.025 mm |
2.2 mm |
15.5 mm |
| 70 mm² |
0.3 mm |
12.5 mm |
0.025 mm |
2.4 mm |
17.5 mm |
| 95 mm² |
0.3 mm |
15.0 mm |
0.025 mm |
2.6 mm |
20.5 mm |
Technical Data:
| Cross sectional area of Cond. |
Appox. weight /100 mtrs roll |
DC resistance of Conduct. at 20° C (Ω/Km) |
Tensile Strength
( N /mm² ) |
| HOFR |
TRS |
| 16 mm² |
24 kg |
1.210 |
11.0 |
9.0 |
| 25 mm² |
35 kg |
0.780 |
11.0 |
9.0 |
| 35 mm² |
45 kg |
0.554 |
11.0 |
9.0 |
| 50 mm² |
62 kg |
0.386 |
11.0 |
9.0 |
| 70 mm² |
86 kg |
0.272 |
11.0 |
9.0 |
| 95 mm² |
115 kg |
0.206 |
11.0 |
9.0 |
Current Carrying Capacity (Amps) at Percentage Duty Cycle
| Cross sectional area of Cond. |
HOFR |
TRS |
| 100 % A |
60 % A |
30 % A |
100 % A |
60 % A |
30 % A |
| 16 mm² |
135 |
174 |
246 |
94 |
121 |
172 |
| 25 mm² |
177 |
228 |
343 |
125 |
161 |
228 |
| 35 mm² |
221 |
285 |
403 |
156 |
201 |
285 |
| 50 mm² |
279 |
360 |
509 |
197 |
254 |
360 |
| 70 mm² |
352 |
454 |
643 |
248 |
320 |
453 |
| 95 mm² |
424 |
547 |
774 |
299 |
386 |
546 |
Go Top
Aluminium Welding Cable
Construction
| Cross sectional area of Cond. |
Diameter of wire |
Dia. of wire Rope |
Polyester Tape Thickness |
Nominal Sheath Thickness |
Max. Overall Diameter |
| 25 mm² |
0.3 mm |
7.5 mm |
0.025 mm |
2.0 mm |
11.5 mm |
| 35 mm² |
0.3 mm |
9.0 mm |
0.025 mm |
2.0 mm |
13.5 mm |
| 50 mm² |
0.3 mm |
10.5 mm |
0.025 mm |
2.2 mm |
15.5 mm |
| 70 mm² |
0.3 mm |
12.5 mm |
0.025 mm |
2.4 mm |
17.5 mm |
| 95 mm² |
0.3 mm |
15.0 mm |
0.025 mm |
2.6 mm |
20.5 mm |
| 120 mm² |
0.3 mm |
17.0 |
0.025 mm |
2.8 mm |
22.5 mm |
Technical Data
| Cross sectional area of Cond. |
Appox. weight /100 mtrs roll |
DC resistance of Conduct. at 20° C (Ω/Km) |
Tensile Strength
( N /mm² ) |
| HOFR |
TRS |
| 25 mm² |
19 kg |
1.230 |
11.0 |
9.0 |
| 35 mm² |
23 kg |
0.901 |
11.0 |
9.0 |
| 50 mm² |
30 kg |
0.634 |
11.0 |
9.0 |
| 70 mm² |
40 kg |
0.445 |
11.0 |
9.0 |
| 95 mm² |
52 kg |
0.334 |
11.0 |
9.0 |
| 120 mm² |
63 kg |
0.256 |
11.0 |
9.0 |
Current Carrying Capacity (Amps) at Percentage Duty Cycle
| Cross sectional area of Cond. |
HOFR |
TRS |
| 100 % A |
60 % A |
30 % A |
100 % A |
60 % A |
30 % A |
| 25 mm² |
144 |
186 |
263 |
100 |
129 |
183 |
| 35 mm² |
176 |
227 |
321 |
123 |
159 |
225 |
| 50 mm² |
222 |
287 |
405 |
155 |
200 |
283 |
| 70 mm² |
280 |
361 |
511 |
196 |
253 |
358 |
| 95 mm² |
339 |
438 |
619 |
237 |
306 |
433 |
| 120 mm² |
404 |
522 |
738 |
283 |
365 |
517 |
Go top
|